3. Click the [Check if the network environment is suitable for
downloading the firmware.] check box to check the network
environment.
4. Click [OK].
NOTE
• The status of the selected Client(s) becomes “Processing” while checking the
network environment, and returns to “Up” after Client(s) receives the firmware.
An error message will appear if the network communication has trouble.
5. Right-click on the target Client and select [Client]-[Store Firmware]
again.
6. If restarting the Client(s) after storing, click the check box of [Restart
the Client after storing the firmware].
NOTE
• If the Client(s) doesn’t restart after storing the firmware, the firmware has not
been updated.
• The Windows XPe-based Client Terminal restarts 3 times automatically. Then,
the stored firmware file will be enabled.
7. Click [OK]. The following warning message will appear.
Click [Yes] to store the firmware in the selected Client Terminal(s).
NOTE
• Follow the warning message if the firmware has not been stored. The wrong
operation will prevent the Client(s) from restarting.
• After the firmware has been updated, restarting the Client(s) causes the IP address
to return to the default. When a DHCP server is not used, any command from
Network Administrator cannot be controlled until an IP address is specified to each
Client directly.